Skip to main content
× Home Services Products Catalogs Downloads Tech Support About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
cart
 
Login Icon
login
Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Agilent TriScroll Pumps On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Edwards nXR Multi Stage Roots Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale

Keyword       Ideal Vacuum Part Number       Manufacturer Part Number

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC TVAC Test Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
Product Image 1
Product Image 2
Product Image 3

Condition:
  New
Part Number:
  P107117
Warranty:
  Against Product Defect

Available Now:  1   Agilent Varian VS Harsh Application Enviornment Probe for Leak Detection. 5m, PN G8600-68002 3898.13


Sale: $3,898.13


×

Load

Print Version

Agilent Varian VS Harsh Application Enviornment Probe for Leak Detection. 5m, PN G8600-68002


Agilent Varian Harsh Evironment Application Probe, KF25 for VS, 936, 959, 979, 990 Series Helium Mass Spectrometer Leak Detectors
Agilent Varian PN G8600-68002.

Power generation facilities, chemical plants and similar facilities require a leak detector to sample gas that is primarily water vapor (steam) and/or contains chemicals that would damage the detector. To prevent this damage from happening, Agilent has developed a specialized probe and leak detector configuration tailored to the demanding requirements of these applications. The VS Harsh Environment (HE) Probe is designed to withstand the wet environment and high temperatures inside condenser piping without the need for dryers, chillers, a secondary vacuum pump, or throttling valves. The probe can either be held or installed in the exhaust of a pump on the condenser system, or can be flange-mounted directly into the piping of the system under test. The probe is connected to the flange via an adjustable compression fitting so the probe tip can be positioned in the center of the pipe. This guarantees the probe tip is in the maximum helium flow for the best sensitivity.

Equipment damage due to corrosion or water in the leak detector or roughing pump is eliminated. The Agilent HE Probe is able to withstand water, amines (ammonia derivatives), and operate at temperatures up to 95 °C (200 °F). The probe is connected directly to a VS Leak Detector with no additional water trapping or auxiliary pumping required. The probe consists of a 5 meter long corrosion resistant 316L stainless steel tube with a composite permeable membrane at its tip. The membrane readily permeates helium tracer gas while protecting the leak detector from water vapor and chemicals that would destroy the pumps, valves, and spectrometer. When the HE Probe is used in conjunction with an Agilent VS Leak Detector equipped with a wireless remote, the manpower needed for a leak test can be cut in half. A single operator can spray helium remotely from the location where the detector is sampling gas, yet can still monitor the instrument’s response. Works with all Agilent Varian 936, 959, 979, 990 and VS PR02, VS MR15, VS MD30, VS BR15, VS BD30 Series Leak Detectors. Agilent Varian Part Number G8600-68002.


Press ESC to Close




You may wish to consider the following products:

Ideal Vacuum Logo Water Mark
CONTACT US
Ideal Vacuum Products, LLC
5910 Midway Park Blvd NE,
Albuquerque, NM 87109-5805

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2