Adixen 2021C2 Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Edwards nXR Multi Stage Roots Pumps On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale

Keyword       Ideal Vacuum Part Number       Manufacturer Part Number

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC TVAC Test Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
Product Image 1
Product Image 2
Product Image 3

Condition:
  New
Part Number:
  P107263
Warranty:
  Against Product Defect

Available Now:  3   Varian Agilent UHV-24 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF Flange, DUAL Tungsten Filament 991.2


Sale: $991.20


×

Load

Print Version

Varian Agilent UHV-24 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF Flange, DUAL Tungsten Filament


Varian Agilent UHV-24 Nude Bayard-Alpert Ionization Gauge, open gauge, Dual Tungsten Filament, 2.75 inch CFF ConFlat Flange,
1×10-3 to 2×10-11 Torr Pressure Range, Maximum Bakeout Temperature: 450 °C

Agilent Varian Part Number 9715008

The Varian Agilent UHV-24 Nude Bayard-Alpert Ionization Gauge is a rugged, open gauge with broad-range operating pressure abilities, Dual Tungsten Filament, 2.75 ConFlat Flange, 1×10-3 to 2×10-11 Torr Pressure Range, Maximum Bakeout Temperature: 450 °C.

The UHV-24 Nude Ionization Gauge, with an x-ray limit of 2x10-11 Torr, provides reliable pressure measurement from 1 mTorr down to 2x10-10 Torr, with reduced performance at pressures lower than 2x10-10 Torr. The UHV-24p Nude Ionization Gauge utilizes an extremely thin collector which lowers its x-ray limit to 5x10-12 Torr. As a result, it can measure pressure from 1m Torr down to 5x10-11Torr, with reduced performance at pressures lower than 5x10-11 Torr.

Properly mounted nude gauges, where the grid structure protrudes into the vacuum chamber, offer the lowest error in terms of the local vacuum pressure being the same as the chamber pressure. The filament is field replaceable. Nude gauges are recommended for bakeable, all-metal, ultra-high vacuum systems where maximum exposure to the vacuum gives the highest possible accuracy. The UHV-24 ion gauge is easily interfaced with Varian's XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool. For complete operating instructions scroll down to (AVAILABLE DOWNLOADS:) and download the Instruction Manual, Spec Sheet and other pertinent information Pdf's. Agilent Varian Part Number 9715008.

Typically Works With Vacuum Gauge Controllers:
  • Granville Phillips Models: 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.

  • MKS Instruments Models: 290, 919, 929

  • Perkin Elmer Model: DGC3

  • Varian Models: 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301, XGS-600

  • Veeco Models: RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002




Press ESC to Close


PDF Logo Varian UHV-24/UHV-24P Bayard-Alpert Ion Gauge Spec Sheet.pdf

PDF Logo Agilent Varian UHV-24 & UHV-24P Hot Cathode Ion Gauges.pdf

PDF Logo Agilent XGS-600 Gauge Controller Brochure.pdf

PDF Logo Aglient XGS-600 Gauge Controller Instruction Manual.pdf